Technology
6 Tested Protective Functions
No promises — proof. Every claim is backed by test reports, standards-based calculations, or documented references.
Solar Reflection
93% of solar radiation reflected
The coating reflects 93% of solar radiation. That means 88% less heat gain through opaque building elements — cooler buildings, less stress on surfaces.
Tested Values
- TSR (Total Solar Reflectance)
- 93 %
- Solar Absorptance αS
- 0.07
- Standard Reference
- ASTM C1549, EN ISO 52016-1
Moisture Protection
Rain stays outside
Liquid water — rain, driving rain, splash water — is almost completely prevented from penetrating. The surface stays dry, thermal protection stays stable.
Tested Values
- Water Absorption
- 0.04 – 0.05 kg/(m³·d⁰·⁵)
- Classification
- W3 (lowest = best)
- Standard Reference
- EN, DIN 4108-4
Vapour Permeability
Moisture can escape
Water vapour from the masonry can continue to escape outward unhindered. The wall dries — no moisture trap, no build-up of dampness.
Tested Values
- Sd Value
- 0.16 – 0.17 m
- Classification
- SD2 (vapour permeable)
- Water Vapour Permeability
- 120 – 128 g/(m²·d), V1
UV Protection
Less thermal stress
The reduction in surface temperature protects underlying materials — render, coatings, wood — from UV-related aging and thermomechanical stress.
Tested Values
- Mechanism
- Surface temperature reduction
- Derived from
- TSR / Emissivity
Lotus Effect / Self-Cleaning
No algae growth, no mould
The hydrophobic surface prevents algae, moss, and mould from colonising. Rainwater beads off and carries dirt particles with it.
Tested Values
- Property
- Hydrophobic surface
- Evidence
- Field references, material properties
Micro-Crack Bridging
Elastic against hairline cracks
The elastic coating bridges existing hairline cracks and prevents new cracks from becoming moisture entry points.
Tested Values
- Property
- Elastic coating
- Evidence
- Material testing, field references
Additional Performance Values
Test values from independent testing per European standards. Actual values may vary depending on substrate, application thickness, and weather conditions.
Technical Documents
OIB-Analyse
Solare Absorptanz und Kühlbedarfsreduktion
PDF, 15 Seiten
Feuchteschutz-Factsheet
Wie Feuchtigkeit den U-Wert verändert
PDF, 3 Seiten
Technisches Datenblatt
Alle Kennwerte kompakt
PDF, 2 Seiten
Technical questions?
Our team is happy to advise you on the technical details and the right solution for your project.
Request technical consultation